2-Way Piloted Diaphragm
General Service Solenoid Valves

Brass and Polymer Bodies » 3/4" - 2" NPT


General Information:
The Economy Line of valves offers a reliable low cost, lightweight and compact alternative to the Industrial Line.  These valves are well suited for humid environments and can be inexpensively modified to meet specific requirements.
(These valves are not intended for use in medical life-support, combustion, aerospace or similar applications)

Mounting Position:
Any Position (best if vertical and upright)

Actuation Response Time:
1 second - 6 seconds is typical

Electrical Specifications:
Standard Voltages:
AC 50/60 Hz: 6, 12, 24, 120, 240
DC: 6, 12, 24
DC Latching: 12, 18, 24

Coil Rating:
Continuous duty totally encapsulated
Class A Rated 105°C; 221°F

Voltage Tolerances:
±10% of applicable voltage

Standard Lead Length: 18" or 24"

DC Latching Valves:
2-Wire (std): 30-50 ms pulse is required for activation; a reversed polarity pulse is required for deactivation. Pulses longer than 50 ms may cause the valve to re-actuate.

Nominal Ambient Temperature Ranges:
0°C to 49°C; 32°F to 120°F

Enclosure Options:
1/2" FPT Conduit (std) - Epoxy potted coil in a glass filled polypropylene housing with integral female conduit connection and 24" leads

1/2" MPT Conduit (120, 240 VAC std) - Fully molded coil in a Valox housing with integral male conduit connection (Class F Rated)

Spade Terminals - Two 1/4" spade terminals integrally molded in a Thermoplastic Polyester housing and open frame design

Din Connection - Form "B" style connection

Canister - Epoxy potted coil in a glass filled nylon canister with two 18" leads wires
(custom wire configurations available)

Operating Modes Available:
Normally Closed - Closed when de-energized, open when energized
Normally Open - Open when de-energized, closed when energized

Valve Parts in Contact with Media:
Body -
Brass or 30% Glass Filled Nylon

Internals -
Brass or Acetal

Base Nut - Brass (std)

Core Tube -
S/S T305

Plunger and Core Plug -
S/S T430F

Shading Ring (AC unites only) -
Copper (std); Silver (special order only)

Springs -
S/S T302

Seals -
Nitrile (std)

Diaphragm -
Nylon Reinforced Nitrile

Options:
• Latching Solenoids

Other voltages, coil constructions, lead lengths and materials are available to meet special requirements.

  Technical Data, Mounting Holes, Flow Patterns


Valve Specifications Solenoid Specification
Add one code from each
Port Size (in) Orifice Size (in) Cv Factor

Operating Press

Max. Operating Temp

Coil Wattage

 

Brass

30% GF Nylon Voltage Enclosure/ Termination
Min. AC
Air/Gas/Water
Max. (MOPD)
DC
Air/Gas/Water
Max. (MOPD)
(psi) (bar) (psi) (bar) (psi) (bar) °F °C AC DC

Normally Closed (Closed When De-Energized)

AC
A205 -
 24-50/60

A210 -
 110/50-
 120/60

A223 -
 220/50-
 240/60

DC
A372 -
 12 VDC

A375-
 24 VDC


SA -
 Spade Term.

LL -
 Din "B"

CB
 1/2" MPT

DC -
 1/2" FPT

CN -
 Canister

3/4 1 10 10 .7 150 10.5 125 8.5 180 82.2 5 6 3108N-662CN
1 10 10 .7 180 12.6 125 8.5 180 82.2 5 6 3108B-662CN
1 10 10 .7 300 21.0       180 82.2 5 6 3108B-672CN   
1 1 14 10 .7 150 10.5 125 8.5 180 65.5 5 6 3110N-662CN
1 14 10 .7 180 12.6 125 8.5 180 82.2 5 6 3110B-662CN
1 14 10 .7 300 21.0       180 82.2 5 6 3110B-672CN   
1-1/2 1-1/2 40 10 .7 150 10.5 125 8.5 180 82.2 5 6 3116B-692CN 3116N-692CN
2 2 56 10 .7 150 10.5 125 8.5 180 82.2 5 6 3120B-712CN 3120N-712CN

Normally Open (Open When De-Energized)

3/4 1 10 10 .7 150 12.6 125 8.5 180 82.2 5 6 3108B-662ON 3108N-662ON
1 1 10 10 .7 150 12.6 125 8.5 180 82.2 5 6 3110B-662ON 3110N-662ON
1-1/2 1-1/2 10 10 .7 150 12.6 125 8.5 180 82.2 5 6 3116B-692ON 3116N-662ON
2 2 10 10 .7 150 12.6 125 8.5 180 82.2 5 6 3120B-712ON 3120N-712ON

 

    
Operational Sequence / Flow Patterns:

2-Way Normally Closed

2-Way Normally Open

Wattage Rating / Power Consumption:

DC

AC

Wattage

Voltage 
(60Hz)

Wattage

Inrush Current 
V ma
Holding Current V ma
6 24 5 385 200
120 5 97 65
240 5 58 37
     AC
     Inrush Amps = Volt-Amp Inrush / Voltage
     Holding Amps = volt-amp Holding / Voltage

     DC
     Since DC valves have no Inrush current, the amp rating can 
     be determined:
     Amps = Watts (DC) / Voltage

Valve Dimensions:

Brass Valves

GF Nylon Valves

Pipe Size A B C Weight
(lbs.)
3/4" 5.29 4.0 4.17 2.10
1" 5.29 4.0 4.57 2.53
1-1/2" 7.1 7.0 6.25 4.20
2" 7.5 7.5 6.75 5.31
Pipe Size A B C Weight
(lbs.)
3/4" 5.98 4.1 4.35 .75
1" 5.98 4.1 4.35 .75
1-1/2" 7.2 7.2 6.3 2.2
2" 7.4 7.4 6.8 2.4
   
Latching Valve 2-Wire Circuit:
Lead Wires:              Red (+)  is for Latching; 
                                 Black (-) is common

Current Pulse:          A 12 VDC 30-50 ms pulse is 
                                 required to latch actuator in the 
                                 open or closed position.  A 
                                 pulse longer than 50 ms may 
                                 cause the armature to re-actuate.


CIE Home | B/C Valve Home | Economy Solenoid Valves | Industrial Solenoid Valves

Last Updated: May 23, 2001