2-Way Direct Acting Manifolds
General Service Solenoid Valves

Acetal Bodies » 1/8" NPT

group 18.jpg (6701 bytes)

General Information:
The Economy Line of valves offers a reliable low cost, lightweight and compact alternative to the Industrial Line.  These valves are well suited for humid environments and can be inexpensively modified to meet specific requirements.
(These valves are not intended for use in medical life-support, combustion, aerospace or similar applications)

Mounting Position:
Any Position (best if vertical and upright)

Actuation Response Time:
20-30 milliseconds is typical

Electrical Specifications:
Standard Voltages:
AC 50/60 Hz: 6, 12, 24, 120, 240
DC: 6, 12, 24
DC Latching: 12, 18, 24

Coil Rating:
Continuous duty totally encapsulated
Class A Rated 105°C; 221°F

Voltage Tolerances:
±10% of applicable voltage

Standard Lead Length: 18" or 24"

DC Latching Valves:
2-Wire (std): 30-50 ms pulse is required for activation; a reversed polarity pulse is required for deactivation. Pulses longer than 50 ms may cause the valve to re-actuate.

Nominal Ambient Temperature Ranges:
0°C to 49°C; 32°F to 120°F

Enclosure Options:
1/2" FPT Conduit (std) - Epoxy potted coil in a glass filled polypropylene housing with integral female conduit connection and 24" leads

1/2" MPT Conduit (120, 240 VAC std) - Fully molded coil in a Valox housing with integral male conduit connection (Class F Rated)

Spade Terminals - Two 1/4" spade terminals integrally molded in a Thermoplastic Polyester housing and open frame design

Din Connection - Form "B" style connection

Canister - Epoxy potted coil in a glass filled nylon canister with two 18" leads wires
(custom wire configurations available)

Operating Modes Available:
Normally Closed - Closed when de-energized, open when energized
Normally Open - Open when de-energized, closed when energized

Valve Parts in Contact with Media:
Body - Acetal
(Other body materials available to meet special requirements)

Base Nut - Brass (std); S/S on S/S Bodies

Core Tube -
S/S T305

Plunger and Core Plug -
S/S T430F

Shading Ring (AC unites only) -
Copper (std); Silver (special order only)

Springs -
S/S T302

Seals -
Nitrile (std)

Options:
• Seals: EPDM, Viton, Silicon, Hydrin, Neoprene
• Latching Solenoids

Other voltages, coil constructions, lead lengths and materials are available to meet special requirements.

  Technical Data, Mounting Holes, Flow Patterns


Valve Specifications Solenoid Specification
Add one code from each
Port Size (in) Orifice Size (in) Cv Factor

Operating Press

Max. Operating Temp Coil Wattage

 

3-Station
4-Station 6-Station Voltage Enclosure/ Termination
Min. AC
Air/Gas/Water
Max. (MOPD)
DC
Air/Gas/Water
Max. (MOPD)
(psi) (bar) (psi) (bar) °F °C AC DC

Normally Closed (Closed When De-Energized)

AC
A205 -
 24-50/60

A210 -
 110/50-
 120/60

A223 -
 220/50-
 240/60

DC
A372 -
 12 VDC

A375-
 24 VDC


SA -
 Spade Term.

LL -
 Din "B"

CB
 1/2" MPT

DC -
 1/2" FPT

CN -
 Canister

1/8 3/64 .046 0 250 17.5 250 17.5 120 49 5 6 1602E-032CN 1702E-032CN 1902E-032CN
1/16 .080 0 250 17.5 200 14.0 120 49 5 6 1602E-042CN 1702E-042CN 1902E-042CN
3/32 .170 0 150 10.5 100 7.0 120 49 5 6 1602E-062CN 1702E-062CN 1902E-062CN

Normally Open (Open When De-Energized)

1/8 1/32 .019 0 250 17.5 250 17.5 120 49 5 6 1602E-022ON 1702E-022ON 1902E-022ON
3/64 .046 0 200 14.0 200 14.0 120 49 5 6 1602E-032ON 1702E-032ON 1902E-032ON
1/16 .080 0 150 10.5 150 10.5 120 49 5 6 1602E-042ON 1702E-042ON 1902E-042ON

 

    
Operational Sequence / Flow Patterns:

2-Way Normally Closed

2-Way Normally Open

Flow Rates - Air / Water:

Flow - Water (GPM)

Flow - Air (SCFM)

Orifice (in) 10 psi 25 psi 50 psi 100 psi 150 psi 200 psi 250 psi 10 psi 25 psi 50 psi 100 psi 150 psi 200 psi 250 psi
3/64 0.15 0.24 0.35 0.46 0.61 0.70 0.80 0.75 1.40 2.00 3.50 5.25 6.75 8.25
1/16 0.24 0.38 0.56 0.80 0.98 1.12 1.28 1.20 2.24 3.20 5.60 8.40 10.80 13.20
3/32 0.51 0.82 1.19 1.70 2.05     2.55 4.76 6.80 11.90 18.60    
(chart shows maximum GPM and SCFM flows by orifice and pressure levels)
  
Wattage Rating / Power Consumption:

DC

AC

Wattage

Voltage 
(60Hz)

Wattage

Inrush Current 
V ma
Holding Current V ma
6 24 5 385 200
120 5 97 65
240 5 58 37
     AC
     Inrush Amps = Volt-Amp Inrush / Voltage
     Holding Amps = volt-amp Holding / Voltage

     DC
     Since DC valves have no Inrush current, the amp rating can be determined:
     Amps = Watts (DC) / Voltage

Valve Dimensions:

Normally Closed Valve shown with canister option

Normally Open Valve shown with canister option

   
Mounting Holes Detail:
   
Latching Valve 2-Wire Circuit:
Lead Wires:              Red (+)  is for Latching; 
                                 Black (-) is common

Current Pulse:          A 12 VDC 30-50 ms pulse is 
                                 required to latch actuator in the 
                                 open or closed position.  A 
                                 pulse longer than 50 ms may 
                                 cause the armature to re-actuate.