Operational Sequence / Flow Patterns:

3-Way Normally Closed

3-Way Normally Open

3-Way Universal

 
Wattage Rating / Power Consumption:
AC DC
Wattage 60 Hz Wattage
VA
Inrush
VA
Holding
10* 46.2 19.8 10**

* NEMA VII models are rated at 11 Watts
** Class H models are rated at 9 Watts

     AC
     Inrush Amps = Volt-Amp Inrush / Voltage
     Holding Amps = volt-amp Holding / Voltage

     DC
     Since DC valves have no Inrush current, the amp rating can be determined:
     Amps = Watts (DC) / Voltage

Valve Dimensions:

3-Way  valve shown with 1/2" MPT option

   
Mounting Holes Detail:
   
Latching Valve 2-Wire Circuit:
Lead Wires:              Red (+)  is for Latching; 
                                 Black (-) is common

Current Pulse:          A 12 VDC 30-50 ms pulse is 
                                 required to latch actuator in the 
                                 open or closed position.  A 
                                 pulse longer than 50 ms may 
                                 cause the armature to re-actuate.