2-Way Direct Acting
General Service Solenoid Valves

Brass or Stainless Steel Bodies » 1/8" - 3/8" NPT

group 18.jpg (6701 bytes)

General Information:
The Industrial Line of valves provides the highest reliability even under the most demanding of applications.  the I11series direct acting valves do not require a minimum operating pressure, which allows them to operate from a "zero" inlet pressure differential (MOPD).  These valves also provide a bubble-tight shutoff and work well with gasses, fluids, light oils and other clean flowing media.

Mounting Position:
Any Position (best if vertical and upright)

Actuation Response Time:
10-40 milliseconds is typical

Electrical Specifications:
Standard Voltages:
VAC 24/60, 110/50-120/60, 220/50-240/60, 440/50-480/60
VDC:12, 24, 48, 120

Coil Rating:
Continuous duty totally encapsulated
Class F Rated 155°C; 311°F

Voltage Tolerances:
+10%, -15% of applicable voltage

Standard Lead Length: 24"

Nominal Ambient Temperature Ranges:
-40°C to 65.5°C; -40°F to 150°F

Enclosure Options:
NEMA I (std)- Metal Housing

NEMA IV - Watertight Housing

NEMA VII - Explosion-Proof Housing
(All options come with 1/2" FPT Conduit Connection)


DIN -
Form "A" Connection

Operating Modes Available:
Normally Closed - Closed when de-energized, open when energized
Normally Open - Open when de-energized, closed when energized

Valve Parts in Contact with Media:
Body - Brass, S/S T316

Core Tube -
S/S T305

Plunger and Core Plug -
S/S T430F

Shading Ring (AC unites only) -
Copper (std); Silver (special order only)

Springs -
S/S T302

Seals -
Nitrile (std on Brass valves); 
Viton (std on S/S valves)

Options:
• Seals: EPDM, Viton, Teflon
• Class H Rated Coil
• Manual Override
• Latching Solenoids

Other voltages, coil constructions, lead lengths and materials are available to meet special requirements.

  Technical Data, Mounting Holes, Flow Patterns


Valve Specifications Solenoid Specification
Add one code from each
Port Size (in) Orifice Size (in) Cv Factor

Operating Press

Max. Operating Temp Coil Wattage

 

Brass
Stainless Steel Voltage Enclosure/ Termination
Min. AC
Air/Gas/Water
Max. (MOPD)
DC
Air/Gas/Water
Max. (MOPD)
(psi) (bar) (psi) (bar) °F °C AC DC

Normally Closed (Closed When De-Energized)

AC
05 -
 24-50/60

10 -
 110/50-
 120/60

23 -
 220/50-
 240/60

40 -
 440/50-
 480/60

DC
72 -
 12 VDC

75-
 24 VDC

Std
D1 -
 NEMA I

Optional
LK
-
 Din "A"

D4
 NEMA IV

D7 -
 NEMA VII

1/8 3/64 .05 0 770 53.9 420 29.4 200 93.3 8 9* I1102F-032CN-F9 I11026-032CV-F9
1/16 .10 0 560 39.2 185 12.9 200 93.3 8 9* I1102F-042CN-F9 I11026-042CV-F9
3/32 .21 0 300 21.0 130 9.1 200 93.3 8 9* I1102F-042CN-F9 I11026-042CV-F9
1/8 .32 0 155 10.8 60 4.2 200 93.3 8 9* I1102F-082CN-F9 I11026-082CV-F9
5/32 .43 0 105 7.3 35 2.4 200 93.3 8 9* I1102F-102CN-F9 I11026-102CV-F9
3/16 .49 0 75 5.2 20 1.4 200 93.3 8 9* I1102F-122CN-F9 I11026-122CV-F9
1/4 3/64 .05 0 1050 73.5 1000 70.0 200 93.3 10 10 I1104F-032CN-F4 I11046-032CV-F4
1/16 .10 0 700 49.0 300 21.0 200 93.3 10 10 I1104F-042CN-F4 I11046-042CV-F4
5/64 .14 0 500 35.0 240 16.8 200 93.3 10 10 I1104F-052CN-F4 I11046-052CV-F4
3/32 .21 0 400 28.0 200 14.0 200 93.3 10 10 I1104F-062CN-F4 I11046-062CV-F4
1/8 .36 0 200 14.0 140 9.8 200 93.3 10 10 I1104F-082CN-F4 I11046-082CV-F4
5/32 .44 0 150 10.5 100 7.0 200 93.3 10 10 I1104F-102CN-F4 I11046-102CV-F4
3/16 .65 0 100 7.0 70 4.9 200 93.3 10 10 I1104F-122CN-F4 I11046-122CV-F4
1/4 .85 0 50 3.5 20 1.4 200 93.3 10 10 I1104F-162CN-F4 I11046-162CV-F4
3/8 1/8 .36 0 200 14.0 140 9.8 200 93.3 10 10 I1105F-082CN-F4 I11056-082CV-F4
3/16 .65 0 100 7.0 70 4.9 200 93.3 10 10 I1105F-122CN-F4 I11056-122CV-F4
9/32 1.0 0 35 2.4 15 1.0 200 93.3 10 10 I1105F-182CN-F4 I11056-182CV-F4
3/8 1.7 0 20 1.4 5 .35 200 93.3 10 10 I1105F-242CN-F4 I11056-242CV-F4

Normally Open (Open When De-Energized)

1/8 3/64 .05 0 350 24.5 350 24.5 200 93.3 8 9* I1102F-032ON-F9 I11026-032OV-F9
1/16 .10 0 200 14.0 200 14.0 200 93.3 8 9* I1102F-042ON-F9 I11026-042OV-F9
3/32 .20 0 105 7.3 105 7.3 200 93.3 8 9* I1102F-062ON-F9 I11026-062OV-F9
1/8 .30 0 60 4.2 60 4.2 200 93.3 8 9* I1102F-082ON-F9 I11026-082OV-F9
1/4 3/64 .05 0 600 42.0 600 42.0 200 93.3 11 10*    I1104F-032OV-F5
1/16 .10 0 325 22.7 325 22.7 200 93.3 11 10*     I1104F-042OV-F5
3/32 .20 0 150 10.5 150 10.5 200 93.3 11 10* I1104F-062ON-F5 I1104F-062OV-F5
1/8 .30 0 100 7.0 100 7.0 200 93.3 11 10* I1104F-082ON-F5 I1104F-082OV-F5
3/16    0 40 2.8 40 2.8 200 93.3 11 10*   I1104F-122OV-F5

* When ordering DC valves, change the base part number as follows:
change '-F9' to '-F7' or change '-F5' to '-F4'  

    
Operational Sequence / Flow Patterns:

2-Way Normally Closed

2-Way Normally Open

Wattage Rating / Power Consumption:
AC DC
Wattage 60 Hz 50 Hz Wattage
VA
Inrush
VA
Holding
VA
Inrush
VA
Holding

Normally Closed

9

10

8 22 11 26 14
10 30 13 37 18

Normally Open

8 30 14 35 19
11 37 16 43 23
The current rating for inrush and holding may be determined by 
dividing the voltage into the  volt-amp rating. 


     AC

     Inrush Amps = Volt-Amp Inrush / Voltage
     Holding Amps = volt-amp Holding / Voltage

     DC
     Since DC valves have no Inrush current, the amp rating can be determined:
     Amps = Watts (DC) / Voltage

Valve Dimensions / Mounting Holes:
Normally Closed
Pipe Size A B C D E F G Weight
(lbs.)
1/8" 1.22 2.78 1.63 .29 .29 .61 .73 0.9
1/4" 1.63 1.63 3.14 1.71 .37 .37 .91 1.1
3/8" 1.63 3.63 2.12 .45 .98 .91 .91 1.3

Normally Open

Pipe Size A B C D E F G Weight
(lbs.)
1/8" 1.22 2.94 1.63 .29 .29 .61 .73 0.9
1/4" 1.63 3.51 1.71 .37 .37 .91 .91 1.1
   
Latching Valve 2-Wire Circuit:
Lead Wires:              Red (+)  is for Latching; 
                                 Black (-) is common

Current Pulse:          A 12 VDC 30-50 ms pulse is 
                                 required to latch actuator in the 
                                 open or closed position.  A 
                                 pulse longer than 50 ms may 
                                 cause the armature to re-actuate.


CIE Home | B/C Valve Home | Economy Solenoid Valves | Industrial Solenoid Valves

Last Updated: May 23, 2001