3-Way Direct Acting/Poppet
General Service Solenoid Valves

Brass or Stainless Steel Bodies » 1/8" - 1/4" NPT

General Information:
The Industrial Line of valves provides the highest reliability even under the most demanding of applications.  the I41series direct acting valves do not require a minimum operating pressure, which allows them to operate from a "zero" inlet pressure differential (MOPD).  The I41 series differs from the I11 series in that coil replacement can be done without disturbing fluid connections. These valves also provide a bubble-tight shutoff and work well with gasses, fluids, light oils and other clean flowing media.

Mounting Position:
Any Position (best if vertical and upright)

Actuation Response Time:
20-40 milliseconds is typical

Electrical Specifications:
Standard Voltages:
VAC 24/60, 110/50-120/60, 220/50-240/60, 440/50-480/60
VDC:12, 24, 48, 120

Coil Rating:
Continuous duty totally encapsulated
Class F Rated 155°C; 311°F

Voltage Tolerances:
+10%, -15% of applicable voltage

Standard Lead Length: 24"

Nominal Ambient Temperature Ranges:
-40°C to 65.5°C; -40°F to 150°F

Enclosure Options:
NEMA I (std)- Metal Housing

NEMA IV - Watertight Housing

NEMA VII - Explosion-Proof Housing
(All options come with 1/2" FPT Conduit Connection)


DIN -
Form "A" Connection

Operating Modes Available:
Normally Closed - Closed when de-energized, open when energized
Normally Open - Open when de-energized, closed when energized
Universal - Either normally open or normally closed

Valve Parts in Contact with Media:
Body - Brass, S/S T303

Poppet - Polyacetal

Core Tube -
S/S T305

Plunger and Core Plug -
S/S T430F

Shading Ring (AC unites only) -
Copper (std); Silver (special order only)

Springs -
S/S T302

Seals -
Nitrile (std on Brass valves); 
Viton (std on S/S valves)

Options:
• Seals: EPDM, Viton, Teflon
• Class H Rated Coil
• Manual Override

Other voltages, coil constructions, lead lengths and materials are available to meet special requirements.

  Technical Data, Mounting Holes, Flow Patterns


Valve Specifications Solenoid Specification
Add one code from each
Port Size (in) Orifice Size (in) Cv Factor

Operating Press

Max. Operating Temp Coil Wattage

 

Brass
Stainless Steel Voltage Enclosure/ Termination
Min. AC
Air/Gas/Water
Max. (MOPD)
DC
Air/Gas/Water
Max. (MOPD)
(psi) (bar) (psi) (bar) °F °C AC DC

Normally Closed (Closed When De-Energized)

AC
05 -
 24-50/60

10 -
 110/50-
 120/60

23 -
 220/50-
 240/60

40 -
 440/50-
 480/60

DC
72 -
 12 VDC

75-
 24 VDC

Std
D1 -
 NEMA I

Optional
LK
-
 Din "A"

D4
 NEMA IV

D7 -
 NEMA VII

1/8 1/16 .09 0 160 11.3 100 7.0 200 93.3 8 9* I4102F-043CN-F9 I41024-043CV-F9
3/32 .15 0 100 7.0 50 3.5 200 93.3 8 9* I4102F-063CN-F9 I41024-063CV-F9
1/8 .26 0 50 3.5 30 2.1 200 93.3 8 9* I4102F-083CN-F9 I41024-083CV-F9
1/4 1/16 .09 0 200 14.0 160 11.3 200 93.3 10 10 I4104F-043CN-F4 I41044-043CV-F4
3/32 .15 0 150 10.5 114 8.0 200 93.3 10 10 I4104F-063CN-F4 I41044-063CV-F4
1/8 .31 0 84 5.9 60 4.2 200 93.3 10 10 I4104F-083CN-F4 I41044-083CV-F4
11/64 .38 0 45 3.2 24 1.7 200 93.3 10 10 I4104F-113CN-F4 I41044-113CV-F4

Normally Open (Open When De-Energized)

1/8 1/16 ..09 0 160 11.3 100 7.0 200 93.3 8 9* I4102F-043ON-F9 I41024-043OV-F9
3/32 .15 0 100 7.0 50 3.5 200 93.3 8 9* I4102F-063ON-F9 I41024-063OV-F9
1/8 .26 0 50 3.5 30 2.1 200 93.3 8 9* I4102F-083ON-F9 I41024-083OV-F9
1/4 1/16 .09 0 200 14.0 160 11.3 200 93.3 10 10 I4102F-043ON-F4 I41044-043OV-F4
3/32 .15 0 150 10.5 114 8.0 200 93.3 10 10 I4104F-063ON-F4 I41044-063OV-F4
1/8 .31 0 84 5.9 60 4.2 200 93.3 10 10 I4104F-083ON-F4 I41044-083OV-F4
11/64   .38 0 45 3.2 24 1.7 200 93.3 10 10  I4102F-113ON-F4 I41044-113OV-F4
Universal (Either Normally open or normally closed)
1/8 1/16 ..09 0 90 6.3 50 3.5 200 93.3 8 9* I4102F-043UN-F9 I41024-043UV-F9
3/32 .15 0 55 3.8 40 2.8 200 93.3 8 9* I4102F-063UN-F9 I41024-063UV-F9
1/8 .26 0 25 1.7 20 1.4 200 93.3 8 9* I4102F-083UN-F9 I41024-083UV-F9
1/4 1/16 .09 0 100 7.0 80 5.6 200 93.3 10 10 I4102F-043UN-F4 I41044-043UV-F4
3/32 .15 0 60 4.2 50 3.5 200 93.3 10 10 I4104F-063UN-F4 I41044-063UV-F4
1/8 .31 0 34 2.4 30 2.1 200 93.3 10 10 I4104F-083UN-F4 I41044-083UV-F4
11/64   .38 0 22 1.5 11 .77 200 93.3 10 10  I4102F-113UN-F4 I41044-113UV-F4

* When ordering DC valves, change the base part number as follows:
change '-F9' to '-F7' 


CIE Home | B/C Valve Home | Economy Solenoid Valves | Industrial Solenoid Valves

Last Updated: May 23, 2001