| Maximum
working pressure |
300 psig (20.7
bar) |
| Maximum
fluid temperature |
200° F (93°
C) - saddle and sensor only
200° F (93° C) - polypropylene and PVDF inline units
140° F (60° C) - molded PVC tee units
140° F (60° C) - when mounted on PVC |
| Ambient
temperature range |
32° F (0° C)
to 110° F (43° C) |
| Enclosure |
NEMA 4X (acceptable
for outdoor use) |
| Sensor accuracy |
± 1% of full
scale reading |
| Repeatability |
± 1% of full
scale reading |
| Power requirements |
15 VDC nominal
(16 - 24 VDC absolute) |
| Model
RT units |
Four standard
AA alkaline batteries or 16 - 24 VDC plug in transformer (batery
life expectancy 1 year minimum) |
| All
other units |
16 - 24 VDC
(plug-in transformer supplied) |
| Model AO
analog output board |
Linear, non-isolated,
powered loop. 250 ohm max for 4 - 20 ma / 500 ohms minimum for
0 - 10 VDC |
| Model PC
process control board |
Relay SPDT,
NO/NC |
| Maximum
switching load |
8 amps @ 115
VAC, 220 VAC, 230 VAC
7 amps @ 30 VDC (resistive load) |
| Maximum
fluid debris size |
0.020" diameter |