PRESSURE DROP - The
graph above shows the expected pressure loss per foot of bed depth as a
function of flow rate at various temperatures.Features
- Complies with USDA & FDA regulations (paragraph 21
CFR173.5) for potable water applications.*
- Reversable exchange of organics.
- Superior, physical stability.
* For potable water applications, the resin must be properly
pre-treated, usually by multiple exhaustion and regeneration cycles, to insure
compliance with extractable levels.
| Physical Properties |
Polymer Structure
Functional Group
Ionic Form, as shipped
Physical Form
Screen Size Distribution
+16 mesh (U.S. Std.)
-40 mesh (U.S. Std.)
-50 mesh (U.S. Std.)
pH Range
Sphericity
Water Retention
Chloride Form
Solubility
Approximate Shipping Weight
Chloride Form
Swelling Ca+2 or Na+ to H+
Total Capacity
Chloride Form |
Unique porous styrene w/ DVB
R-N-(CH3)3+X-
Chloride
Tough, spherical beads
30 to 50 nominal
<10 percent
<10 percent
<1 percent
0 to 14
95+ percent
60 to 75 percent
Insoluble
41 lbs/ft3
32 percent
0.55 to 0.75 meq/ml min |
|
ProSelect Tannin is the choice
for color, organics, and tannin contaminated waters. It works as an organic
screen, either as a stand alone prefilter for a softener, or in some
applications as a media which is simply added to an existing softener.
ProSelect Tannin will sit on top of the existing softening bed to protect it
and remove organic (heme) iron as well. ProSelect Tannin regenerates with
salt.
CAUTION: DO NOT MIX ION EXCHANGE
RESINS WITH STRONG OXIDIZING AGENTS. Nitric acid and other strong
oxidizing agents can cause explosive reactions when mixed with organic
materials such as ion exchange resins.
Note: These suggestions and data
are based on information we believe to be reliable. However, we do not make any
guarantee or warranty. We caution against using these products in any unsafe
manner or in violation of any patents. Further, we assume no liability for the
consequences of any such actions.
| Suggested
Operating Conditions |
Maximum Temperature
Chloride Form
|
170°F |
| Minimum Bed Depth |
24 inches |
Backwash Rate
50% Bed Expansion @ 60ºF |
1.9 gpm
|
| Regenerant |
10%
NaCl & 0.5% NaOH mixture |
| Regenerate Flow Rate |
0.2 to 0.5 gpm/ft3 |
| Regenerate Contact Time |
At least 60 minutes |
| Regenerate Level |
10 to 15 lbs/ft3 plus
proptional amount of NaOH |
| Displacement Rinse Rate |
Same as Regenerate Flow
Rate |
| Displacement Rinse Volume
|
10 to 15 gal/ft3 |
| Fast Rinse Rate |
Same as Service Flow
Rate |
| Fast Rinse Volume |
35 to 60 gal/ft3 |
| Service Flow Rate |
1 to 4 gpm/ft3 |
|