PRESSURE DROP - The graph above
shows the expected pressure loss per foot of bed depth as a function of flow
rate at various temperatures.Features
- Complies with USDA & FDA regulations (paragraph 21
CFR173.5) for potable water applications.*
- Uniform particle size, low pressure drop.
- Superior, physical stability.
- Organic fouling resistance high operating capacity.
* For potable water applications, the resin must be properly
pre-treated, usually by multiple exhaustion and regeneration cycles, to insure
compliance with extractable levels.
| Operating Capacity |
Pounds
NaCl/ft |
Capacity
Kilograins/ft |
| 4 |
11.5 |
| 6 |
13.5 |
| 8 |
15.2 |
| 10 |
16.8 |
|
|
Note: These
suggestions and data are based on information we believe to be reliable.
However, we do not make any guarantee or warranty. We caution against
|
| using these products in any
unsafe manner or in violation of any patents. Further, we assume no liability
for the consequences of any such actions. |
|
|
ProSelect Silica: If youve
run into silica problems in the past, you know how hard it is to take care of
them. Now, weve formulated the perfect resin to work hand-in-hand with
our ProSoft Premium softening resin for the purpose of silica removal. At
SWT, we respond to your needs.
CAUTION: DO NOT MIX ION EXCHANGE
RESINS WITH STRONG OXIDIZING AGENTS. Nitric acid and other strong
oxidizing agents can cause explosive reactions when mixed with organic
materials such as ion exchange resins.
| Physical Properties |
Polymer Structure
Functional Group
Ionic Form, as shipped
Physical Form
Screen Size Distribution
+16 mesh (U.S. Std.)
-40 mesh (U.S. Std.)
-50 mesh (U.S. Std.)
pH Range
Sphericity
Uniformity Coefficient
Water Retention
Chloride Form
Hydroxide Form
Solubility
Approximate Shipping Weight
Chloride Form
Hydroxide Form
Swelling Ca+2 or Na+ to H+
Total Capacity
Chloride Form
Hydroxide Form |
Unique porous styrene w/ DVB
R-N-(CH3)3+X-
Chloride or Hydroxide
Tough, spherical beads
16 to 45 nominal
<2 percent
<2 percent
<1 percent
0 to 14
93+ percent
Approx. 1.6
51 to 57 percent
65 to 70 percent
Insoluble
43 lbs/ft3
50 lbs/ft3
20 to 27 percent
1.25 meq/ml min
1.0 meq/ml min |
| Suggested
Operating Conditions |
Maximum Temperature
Chloride Form
Hydroxide Form
|
170ºF
140°F |
| Minimum Bed Depth |
24 inches |
Backwash Rate
50% Bed Expansion @
60ºF |
2.2 gpm/ft
|
Regenerant
|
2 to 6%
|
| Regenerate Flow Rate |
0.25 to 1.0 gpm/ft |
| Regenerate Contact Time |
At least 60 minutes |
| Regenerate Level |
4 to 10 lbs/ft |
| Displacement Rinse Rate |
Same as Regenerate Flow
Rate |
| Displacement Rinse Volume
|
10 to 15 gal/ft3 |
| Fast Rinse Rate |
Same as Service Flow
Rate |
| Fast Rinse Volume |
35 to 60 gal/ft3 |
| Service Flow Rate |
2 to 4 gpm/ft3 |
|