| BetterLife Water Treatment
Systems with UV Sterilization |
| Part Number |
Description |
Service Flow Rate Taste,
Odor & Chlorine |
Service Flow Rate VOC
Red. |
Service Peak Flow
Rate |
Backwash 30% Exp. @
50ºF |
Standard Connection
Size |
| BL1-100 |
10 x 47" Tnk |
5 gpm |
2 gpm |
10 gpm |
4.3 gpm |
¾" Copper Swet |
| BL1-175 |
12 x 48" Tnk |
10 gpm |
4 gpm |
10 gpm |
8.0 gpm |
¾" Copper Swet |
|
| BL1-100R |
10 x 47" Tnk |
5 gpm |
2 gpm |
10 gpm |
4.3 gpm |
¾" Copper Swet |
| BL1-175R |
12 x 48" Tnk |
10 gpm |
4 gpm |
10 gpm |
8.0 gpm |
¾" Copper Swet |
| Options and
Upgrades |
| Part No. Suffix |
Description |
| -P |
1 Micron Absolute Postfilter Assembly For Cryptosporidium
and Giardia Cyst Removal |
| -R |
10 Micron Prefilter with 20" Clear, Bypass Housing -
Highly Recommended For Rural Applications |
| -S |
Solenoid Valve Assembly - Requires Upgraded Electronic
Ballast |
| -A |
Controller Board with Lamp Status LED, Audible Alarm, and
Solenoid Valve Hook-up |
| -E |
Instant Start Electronic Ballast
(Auto-detects 50/60 Hz) |
| -? |
Other Media Substitutions Available - Call for Additional
Information |
Warning and Disclaimer: Ultraviolet treatment, chlorinating, or
any other form of sanitation of contaminated water, is never a 100% guaranteed
for bacteriological free water, but are EPA approved methods of water
sanitation which add greatly to protection against waterborne pathogens. Proper
ultraviolet sterilization is an instantaneous process which destroys 99.97% of
pathogens and leaves no UV residual in the water. Periodic monitoring of the
water supply and of the down stream piping system sanitation is recommended to
help guard against downstream contamination or accidental contaminated water
bypass. Ultraviolet sterilization and/or chlorine, is not recommended and
should not be used for cyst treatment.
| Replacement Parts
|
| Part No. |
Description |
| IL10001 |
Ultraviolet Lamp |
| CF73210 |
10 Micron Pleated Sediment Cartridge (2.5"x20"
Pre-filter) |
| AH-PPBB210 |
1 Micron Absolute Pleated Cartridge for Cryptosporidium and
Giardia Cysts (4.5 x 20" Post-Filter) |
| APS-CSR |
Replacement Chlorastick Pipe
Sanitizing Module |
| IL30001 |
Quartz Sleeve |
| UL-118RS |
Red Silicone O-Ring for Quartz
Sleeve |
| EC-LL68 |
Safety Spring |
| MA-155153-43 |
Granular Activated Carbon Cartridge for Big Blue Housing
(4.5 x 20") |
 |
 |
 |
Chlorastick Pipe Sanitizing Kit (Included)
Contains:
- Brass, Lever Action
- Brass Ball Valves
- Quick Release Union Fittings w/ O-Ring Seals
- Disposable Chlorine Chamber
- Sch 80 PVC Replacement Pipe
|
Pre-filter Assembly (Optional)
Contains:
- 20 Clear Housing w/ Built-in Bypass, &
¾ NPT
- 2.5 x 20 Pleated Cartridge w/ 10 Micron
Filtration
- Spanner Wrench
- Wall Mount Bracket
|
Post-filter Assembly
(Optional)
Contains:
- 20 Big Blue Sump w/ PR & ¾ NPT
- 4.5 x 20 Pleated Cartridge w/ 1 Micron
Filtration for Giardia Cysts
- Spanner Wrench
- Wall Mount Bracket
|
| Additional
Specifications - BetterLife Systems |
| Shipping Dimensions (Inches): |
| BL2-100: |
17 x 13 x 58 @ 80 LBS. |
|
|
17 x 13 x 59 @ 115 LBS. |
|
| Operating Pressure: 20 - 125 PSI |
| Operating Temperature: 36 - 120ºF (2 -
48.9ºC) |
|
|