| FILTERS -
MANUAL CONTROLLER W/ STAGER |
| MODEL NUMBER |
DESCRIPTION |
| RO48-0100-000A |
FILTER, 3 CYCLE, SINGLE TANK |
FILTERS - TIME INITIATED CONTROLLER W/
STAGER |
| MODEL NUMBER |
DESCRIPTION |
| A148-01 |
FILTER, 3 CYCLE, SINGLE TANK |
| A151-10 |
FILTER, 3 CYCLE, TWO TANKS PARALLEL W/
SEQUENTIAL BACKWASH |
| A158-03 |
FILTER, 3 CYCLE, THREE TANKS PARALLEL W/
SEQUENTIAL BACKWASH |
| A158-04 |
FILTER, 3 CYCLE, FOUR TANKS PARALLEL W/
SEQUENTIAL BACKWASH |
PLEASE SPECIFY VOLTAGE REQUIREMENT. 120V/60Hz
IS STANDARD; 220V/50Hz OR 220V/60Hz ARE AVAILABLE.
PLEASE SPECIFY IF 6 OR 7 DAY CLOCK TIMER IS NEEDED. IF NOT SPECIFIED, THE
CONTROLLER WILL BE SUPPLIED WITH 6 DAY TIMER. |
SOFTENERS - MANUAL CONTROLLER W/
STAGER |
| MODEL NUMBER |
DESCRIPTION |
| RO48-0000-000A |
SOFTENER, 5 CYCLE, SINGLE TANK |
SOFTENERS - TIME INITIATED CONTROLLER W/
STAGER |
| MODEL NUMBER |
DESCRIPTION |
| A148-00 |
SOFTENER, 5 CYCLE, SINGLE TANK |
| A158TA |
SOFTENER, 5 CYCLE, TWIN ALTERNATING |
PLEASE SPECIFY VOLTAGE REQUIREMENT. 120V/60Hz
IS STANDARD; 220V/50Hz OR 220V/60Hz ARE AVAILABLE.
PLEASE SPECIFY IF 6 OR 7 DAY CLOCK TIMER IS NEEDED. IF NOT SPECIFIED, THE
CONTROLLER WILL BE SUPPLIED WITH 6 DAY TIMER. |
SOFTENERS - DEMAND/METERED INITIATED CONTROLLER W/
STAGER (AQUAMATIC CONTROLLER) |
| MODEL NUMBER |
DESCRIPTION |
| 7000A-A258 |
SOFTENER, 5 CYCLE, SINGLE TANK (MAY BE USED IN PARALLEL OPERATION - ONE FORE EACH TANK)
|
| 7000A-58BTA |
SOFTENER, 5 CYCLE, TWIN ALTERNATING
|
DOES NOT INCLUDE FLOW METER
7000A CONTROLLER IS INSTALLED IN SAME ENCLOSURE W/ STAGER
PLEASE SPECIFY VOLTAGE REQUIREMENT. 120V/60Hz IS STANDARD; 220V/50Hz OR
220V/60Hz ARE AVAILABLE. |
SOFTENERS - DEMAND/METERED INITIATED CONTROLLER W/
STAGER (BADGER CONTROLLER) |
| MODEL NUMBER |
DESCRIPTION |
| AR/E-A258 |
SOFTENER, 5 CYCLE, SINGLE TANK
(MAY BE USED IN PARALLEL OPERATION - ONE FORE EACH TANK) |
DOES NOT INCLUDE FLOW METER
AR/E CONTROLLER IS IN SEPARATE NEMA 4X ENCLOSURE
PLEASE SPECIFY VOLTAGE REQUIREMENT. 120V/60Hz IS STANDARD; 220V/50Hz OR
220V/60Hz ARE AVAILABLE. |
SOFTENERS - DEMAND/METERED INITIATED CONTROLLER W/
STAGERS & METERS (AUTOTROL CONTROLLER) |
| MODEL NUMBER |
DESCRIPTION |
| 480QC-A258-10 |
SOFTENER, 5 CYCLE, SINGLE TANK, 1" NPT
TURBINE METER (35 GPM MAXIMUM FLOW RATE) |
| 480QC-A258-20 |
SOFTENER, 5 CYCLE, SINGLE TANK, 2" NPT
TURBINE METER (170 GPM MAXIMUM FLOW RATE) |
| 480QC-A258-1T |
SOFTENER, 5 CYCLE, TWIN ALTERNATING, 1"
NPT TURBINE METER (35 GPM MAXIMUM FLOW RATE)
|
| 480QC-A258-2T |
SOFTENER, 5 CYCLE, TWIN ALTERNATING, 2"
NPT TURBINE METER (170 GPM MAXIMUM FLOW RATE)
|
| 480QC-A258-12 |
SOFTENER, 5 CYCLE, TWO TANK PARALLEL OPERATION,
1" NPT TURBINE METER (35 GPM MAXIMUM FLOW RATE)
|
| 480QC-A258-22 |
SOFTENER, 5 CYCLE, TWO TANK PARALLEL OPERATION,
2" NPT TURBINE METER (170 GPM MAXIMUM FLOW RATE)
|
| 480QC-A258-13* |
SOFTENER, 5 CYCLE, THREE TANK PARALLEL
OPERATION, 1" NPT TURBINE METER (2 IN SERVICE/1 IN STANDBY
OR 3 IN SERVICE) (35 GPM MAX.) |
| 480QC-A258-23* |
SOFTENER, 5 CYCLE, THREE TANK PARALLEL
OPERATION, 2" NPT TURBINE METER (2 IN SERVICE/1 IN STANDBY
OR 3 IN SERVICE) (170 GPM MAX.) |
480QC CONTROLLER IS IN SEPARATE NEMA 4
ENCLOSURE AND INCLUDES 14 FOOT CABLE FOR EACH TANK
*PLEASE SPECIFY MODE OF OPERATION: (A)=2 IN SERVICE/1 IN STANDBY OR (P)=3 IN
SERVICE |
FLOW METERS (NEEDED FOR ALL 7000A
& AR/E DEMAND SYSTEMS) |
BADGER |
| MODEL NUMBER |
DESCRIPTION |
CONTROLLER |
| M70-RTR |
1" MPT BRONZE DISC METER W/ PULSE TRANSMITTER, W/O
UNION CONN. (70 GPM MAXIMUM FLOW RATE) |
7000A & AR/E |
| M70-RTR-U |
1" FPT BRONZE DISC METER W/ PULSE TRANSMITTER &
UNION CONN. (70 GPM MAXIMUM FLOW RATE) |
7000A & AR/E |
| M170-RTR |
2" FPT BRONZE DISC METER W/ PULSE TRANSMITTER, W/O
UNION CONN. (170 GPM MAXIMUM FLOW RATE) |
7000A & AR/E |
| M170-RTR-U |
2" FPT BRONZE DISC METER W/ PULSE TRANSMITTER &
UNION CONN. (170 GPM MAXIMUM FLOW RATE) |
7000A & AR/E |
| RCDL450-RTR |
3" ANSI FLANGE BRONZE TURBO METER W/ PULSE
TRANSMITTER (450 GPM MAXIMUM FLOW RATE) |
7000A & AR/E |
AUTOTROL |
| MODEL NUMBER |
DESCRIPTION |
CONTROLLER |
| ATM-1 |
1" MPT PLASTIC TURBINE METER W/ BRASS UNION
CONNECTIONS & 10 FOOT CABLE (35 GPM MAXIMUM FLOW
RATE) |
7000A |
| ATM-2 |
2" MPT PLASTIC TURBINE METER W/ BRASS UNION
CONNECTIONS & 10 FOOT CABLE (170 GPM MAXIMUM FLOW RATE)
|
7000A |
| ATM-3T |
3"FPT PVC TEE MOUNTED FLOW SENSOR (450 GPM MAXIMUM FLOW RATE) |
7000A |
| ATM-3U |
3"FPT PVC TEE MOUNTED FLOW SENSOR W/UNION CONNECTORS
(450 GPM MAXIMUM FLOW RATE) |
7000A |