| With proper
installation and maintenance the RO membrane module in the Premium Reverse
Osmosis System will reject the following substances from tap water.
Arsenic
Barium
Bicarbonate
Boron
Bromide
Cadmium
Calcium
Chloride
Copper
Cyanide
Flouride
Hardness
Iron
Lead
Magnesium
Manganese
Mercury
Nickel
Nitrate
Phosphate
Potassium
Pyrogen
Selenium
Silica
Silicate
Silver
Sodium
Strontium
Sulfate
Zinc |
94-96%
98-96%
95-96%
60-70%
93-96%
96-98%
94-97%
87-95%
98-99%
86-95%
94-96%
95-98%
95-98%
96-98%
96-98%
98-99%
96-98%
98-99%
90-96%
96-99%
87-97%
98-99%
96-98%
85-90%
95-97%
85-97%
87-98%
96-98%
98-99%
98-99% |
|
|
The Premium Revese
Osmosis System has two carbon filtration modules which will remove, or
significantly reduce, over 50 chemical substances that the EPA has deemed
potential carcinogens. They include: |
|
Adipates
(diethylhexyl)
Alachor
Aldicarb
Atrazine
Benz (a) anthracine (PAH)
Benzene
Benzo
Butyl benzyl phthalate (PAE)
Cadmium
Carbofuran
Carbon tetrachloride
Chlordane
Chlorine
Chrysene
Dalapon
Di (20ethylhexl) adipate
Dibenz (a,h) antracene
Dibromochloropropane |
Dichlorobenzene
Dichloroethane (1,2-)
Dichloroethylene
Dichloropropane
Diethylhexyl phthalate (PAE)
Dinoseb
Diquat
Endothall
Endrin
Ethylbenzene
Ethelene dibromide (EDB)
Glyphosate
Heptachlor
Hexachlorobenzene
Hexachlorocyclopentadiene
Indo (1,2,3-c,d) pyrene (PAH)
Lidane
Mercury (organic complexes)
Methoxychlor |
Methylene
Blue
Monochlorobenzene
Oxymal
Pentachlorophenal
Picloram
PCB's
Simarzine
Styrene
2,3,7,8-TCDD (dioxin)
2,4,5-TP (silvex)
TCB's
TCE's
Tetrachloroethylene
THM's
Toulene
Toxaphane
Vinyl chloride
Xylenes |
|
|
| GENERAL INSTALLATION AND
SERVICE PARAMETERS |
The Premium RO System will work
at peak efficiency on either municipal or ground water supplies that do not
exceed the following:
Maximum psi
TDS
Iron
Hardness
Hydrogen Sulfide
Manganese |
125 lbs.
1800 ppm
0.4 ppm
17 gr/gal
0.05 ppm
0.1 ppm |
The Premium has been designed to give many years of trouble
free service. To keep the system operating in peak efficiency, it is expected
every six months for possible prefilter sediment clogging (especially if there
is a lot of sediment in the water supply). |
The manufacturer recommends that
the system be serviced an an annual basis to replace all of the carbon filters,
the RO module*, and the UV lamp. * The Premium RO
module may last for a much longer period of time on relatively good water.
Check with your water Water Treatment Professional for local water
characteristics and testing.
|
|
|